DN15–25 Water Flow Calibration Device (Piston Prover Method + Gravimetric Method)
Tell us the meter size, test method and required testing capacity.
DN15–25 water flow calibration device, piston prover + gravimetric. Request configuration details from KINMY.
- Nominal Diameter
- DN15–25
- Test Method
- Piston Prover Method + Gravimetric Method
Overview
DN15–25 Water Flow Calibration Device (Piston Prover Method + Gravimetric Method) is listed in the KINMY Liquid Flow Calibration Device range with a configuration identified by DN15–25, Piston Prover Method + Gravimetric Method. Contact KINMY for a project-specific specification sheet and quotation.
Configuration
| Nominal Diameter | DN15–25 |
|---|---|
| Test Method | Piston Prover Method + Gravimetric Method |
Measurement and Test Methods
| Measurement principles | Piston Prover Method + Gravimetric Method |
|---|---|
| Reference flow range | 0.003–8 m³/h |
| Measurement modes | Start-Stop Method, Reversal Method, Flow-Time Method |
Reference Standards and Instruments
Reference equipment listed for this catalog configuration. The supplied instrument set is confirmed with the project specification.
| Weighing Instruments | Electronic balances; listed maximum capacities: 30 kg, 150 kg |
|---|
Reference Specifications
| Measurement Uncertainty | Urel ≤ 0.05% (k=2) |
|---|---|
| Flow Stability | 1.0% for Start-Stop Method; 0.2% for Other Methods |
| Calibration Medium | Pure Tap Water |
| Operating Humidity | ≤ 93% RH |
| Operating Water Temperature | 20℃ ± 10℃ |
| Device Operating Temperature | 4℃-50℃ |
| Water Source Operating Pressure | 0.0-0.5 MPa (Adjustable) |
| Air Source Operating Pressure | 0.4-0.7 MPa |
| Number of Meters Under Test | DN15: 10 units | DN20: 8 units | DN25: 6 units | Vertical Water Meters (DN15, DN20, DN25): 6 units |
| Meter Clamping Mechanism | Dual-Cylinder External-Push Tandem Meter Clamping Device; Single Pneumatic Clamping Device for 10 Front 5 Rear Positions |
| Vacuum System | Differential-Pressure Vacuum Generator, Vacuum Priming, Maintains Water Meters in Full-Water State |
| Supported Test Modes | Fully Automatic, Semi-Automatic, Touchscreen Manual |
Utilities and System Configuration
| Water pump configuration | Nanfang CHM10-50, Flow Rate: 8 m³/h, Head: 48 m, 1 unit |
|---|---|
| Water tank capacity | 800 L |
| Flow diverter | DN25 Cross-Type Pneumatic Open Reverser, Low Noise & High Sensitivity, Stroke Difference 10 ms, Uncertainty ≤ 0.002% |
| Timing system | (10-100) kHz (Adjustable); Accuracy Better Than 10⁻⁶ |
| Pulse acquisition signal | Pulse, f = (0~10) kHz |
| Data acquisition hardware | 16 Mobile Phones (Camera Resolution ≥ 40 Million Pixels) |
| Tightness test pressure range | (0~2.0) MPa |
Request Specifications
Final configuration, test range and supplied components can vary by project and selected method. Please send your meter sizes, required test method and expected testing capacity for confirmation.
Related products
-
DN15–100 Fully Automatic Heat Meter Test Bench (Gravimetric Method + Reference Meter Method)
-
DN15–100 Fully Automatic Heat Meter Test Bench (Gravimetric Method)
-
DN15–100 Fully Automatic Water Flow Calibration Device (Gravimetric Method + Reference Meter Method)
-
DN15–100 Fully Automatic Water Flow Calibration Device (Gravimetric Method)
-
DN15–100 Fully Automatic Water Flow Calibration Device (Reference Meter Method)