DN15–100 Fully Automatic Heat Meter Test Bench (Reference Meter Method)
Tell us the meter size, test method and required testing capacity.
DN15–100 heat meter test bench, reference meter, fully automatic. Request configuration details from KINMY.
- Nominal Diameter
- DN15–100
- Test Method
- Reference Meter Method
- Automation
- Fully Automatic
Overview
DN15–100 Fully Automatic Heat Meter Test Bench (Reference Meter Method) is listed in the KINMY Heat Meter Test Bench range with a configuration identified by DN15–100, Reference Meter Method, Fully Automatic. Contact KINMY for a project-specific specification sheet and quotation.
Configuration
| Nominal Diameter | DN15–100 |
|---|---|
| Test Method | Reference Meter Method |
| Automation | Fully Automatic |
Measurement and Test Methods
| Measurement principles | Reference Meter Method |
|---|---|
| Reference flow range | 0.010–130 m³/h |
| Measurement modes | Start-Stop Method, Flow-Time Method |
Reference Standards and Instruments
Reference equipment listed for this catalog configuration. The supplied instrument set is confirmed with the project specification.
| Reference meters | Electromagnetic reference flowmeters |
|---|---|
| Temperature reference equipment | Standard platinum resistance thermometer (SPRT); digital multimeter for temperature acquisition; constant-temperature baths |
Product Highlights
- Compact size, small footprint, corrosion resistant, and equipped with wheels for easy movement.
- 2.7-inch touchscreen panel for setting pressure, vacuum pressure, pressure time, and vacuum water injection time.
- Pneumatic quick clamping, faster and more efficient than traditional hydraulic clamping, requiring no external high-pressure water source.
- One-button start, one-button selection (manual or automatic), safe operation.
- Suitable for mass production, used in conjunction with fully automatic Water Meter Test Benchs and automatic meter Meter Screwing Machines to improve production cycle time and increase capacity.
- Low power consumption, energy-saving, requires only one operator, saving labor and time.
Reference Specifications
| Measurement Uncertainty | Urel ≤ 0.2% (k=2) |
|---|---|
| Flow Stability | 1.0% for Start-Stop Method; 0.2% for Other Methods |
| Calibration Medium | Pure Tap Water |
| Operating Humidity | ≤ 93% RH |
| Operating Water Temperature | 20℃ ± 10℃ |
| Device Operating Temperature | 4˜50℃ |
| Water Source Operating Pressure | 0.0-0.5 MPa (Adjustable) |
| Air Source Operating Pressure | 0.4-0.7 MPa |
| Number of Meters Under Test | DN15: 10 units | DN20: 8 units | DN25: 6 units | DN40, DN50, DN65: 5 units | DN80, DN100: 3 units |
| Meter Clamping Mechanism | Dual-Cylinder External-Push Tandem Meter Clamping Device; Single Pneumatic Clamping Device for 10 Front 5 Rear Positions |
| Vacuum System | Differential-Pressure Vacuum Generator, Vacuum Priming, Maintains Water Meters in Full-Water State |
| Supported Test Modes | Fully Automatic, Semi-Automatic, Touchscreen Manual |
Utilities and System Configuration
| Water pump configuration | H=20 m; Q=2 m³/h; P=0.5 kW, 1 unit | H=30 m; Q=40 m³/h; P=7.5 kW, 1 unit | H=30 m; Q=180 m³/h; P=22 kW, 1 unit |
|---|---|
| Water tank capacity | 15000 L |
| Flow diverter | DN25 DN100 Cross-Type Pneumatic Open Reversers, Low Noise High Sensitivity, Stroke Difference 10 ms, Uncertainty ≤ 0.002% |
| Timing system | (10-100) kHz (Adjustable); Accuracy Better Than 10⁻⁶ |
| Pulse acquisition signal | Pulse, f = (0˜10) kHz |
| Data acquisition hardware | 5 Mobile Phones (50 MP Pixels, 8G/128G Storage) |
| Tightness test pressure range | (0˜2.0) MPa |
Request Specifications
Final configuration, test range and supplied components can vary by project and selected method. Please send your meter sizes, required test method and expected testing capacity for confirmation.
Related products
-
DN15–100 Fully Automatic Heat Meter Test Bench (Gravimetric Method + Reference Meter Method)
-
DN15–100 Fully Automatic Heat Meter Test Bench (Gravimetric Method)
-
DN15–100 Fully Automatic Pressure Tester
-
DN15–100 Fully Automatic Water Flow Calibration Device (Gravimetric Method + Reference Meter Method)
-
DN15–100 Fully Automatic Water Flow Calibration Device (Gravimetric Method)