DN15–25 Fully Automatic Heat Meter Test Bench (Piston Prover Method + Gravimetric Method)
Tell us the meter size, test method and required testing capacity.
DN15–25 heat meter test bench, piston prover + gravimetric, fully automatic. Request configuration details from KINMY.
- Nominal Diameter
- DN15–25
- Test Method
- Piston Prover Method + Gravimetric Method
- Automation
- Fully Automatic
Overview
DN15–25 Fully Automatic Heat Meter Test Bench (Piston Prover Method + Gravimetric Method) is listed in the KINMY Heat Meter Test Bench range with a configuration identified by DN15–25, Piston Prover Method + Gravimetric Method, Fully Automatic. Contact KINMY for a project-specific specification sheet and quotation.
Configuration
| Nominal Diameter | DN15–25 |
|---|---|
| Test Method | Piston Prover Method + Gravimetric Method |
| Automation | Fully Automatic |
Measurement and Test Methods
| Measurement principles | Piston Prover Method+Gravimetric Method |
|---|---|
| Reference flow range | 0.003–8 m³/h |
| Measurement modes | Start-Stop Method, Reversal Method, Flow-Time Method |
Reference Standards and Instruments
Reference equipment listed for this catalog configuration. The supplied instrument set is confirmed with the project specification.
| Weighing Instruments | Electronic balances; listed maximum capacities: 30 kg, 150 kg |
|---|---|
| Temperature reference equipment | Standard platinum resistance thermometer (SPRT); digital multimeter for temperature acquisition; constant-temperature baths |
Product Highlights
- High Production Efficiency: 300 water meters can be tested in eight hours.
- Fast Input Method: Wireless barcode scanner input of meter numbers, fast, accurate, and convenient.
- Energy Saving and Consumption Reduction: Saves water, electricity, and labor.
- Compact Size: Saves space, fully automated, shares a network, and saves auxiliary materials.
- Novel Structure: European standard aluminum profile frame, 304 stainless steel piping, novel and stylish appearance.
Reference Specifications
| Measurement Uncertainty | Urel ≤ 0.2% (k=2) |
|---|---|
| Flow Stability | 1.0% for Start-Stop Method; 0.2% for Other Methods |
| Calibration Medium | Pure Tap Water |
| Operating Humidity | ≤ 93% RH |
| Operating Water Temperature | 20℃ ± 10℃ |
| Device Operating Temperature | 4˜50℃ |
| Water Source Operating Pressure | 0.0-0.5 MPa (Adjustable) |
| Air Source Operating Pressure | 0.4-0.7 MPa |
| Number of Meters Under Test | DN15: 10 units | DN20: 8 units | DN25: 6 units | Vertical Water Meters (DN15, DN20, DN25): 6 units |
| Meter Clamping Mechanism | Dual-Cylinder External-Push Tandem Meter Clamping Device; Single Pneumatic Clamping Device for 10 Front 5 Rear Positions |
| Vacuum System | Differential-Pressure Vacuum Generator, Vacuum Priming, Maintains Water Meters in Full-Water State |
| Supported Test Modes | Fully Automatic, Semi-Automatic, Touchscreen Manual |
Utilities and System Configuration
| Water pump configuration | Nanfang CHM10-50, Flow Rate: 8 m³/h, Head: 48 m, 1 unit |
|---|---|
| Water tank capacity | 800 L |
| Flow diverter | DN25 Cross-Type Pneumatic Open Reverser, Low Noise High Sensitivity, Stroke Difference 10 ms, Uncertainty ≤ 0.002% |
| Timing system | (10-100) kHz (Adjustable); Accuracy Better Than 10⁻⁶ |
| Pulse acquisition signal | Pulse, f = (0˜10) kHz |
| Data acquisition hardware | 16 Mobile Phones (Camera Resolution ≥ 40 Million Pixels) |
| Tightness test pressure range | (0˜2.0) MPa |
Request Specifications
Final configuration, test range and supplied components can vary by project and selected method. Please send your meter sizes, required test method and expected testing capacity for confirmation.
Related products
-
DN15–100 Fully Automatic Heat Meter Test Bench (Gravimetric Method + Reference Meter Method)
-