Home›Products›Heat Meter Test Bench›DN50–200 Fully Automatic Flat Layout Heat Meter Test Bench (Gravimetric Method)

DN50–200 Fully Automatic Flat Layout Heat Meter Test Bench (Gravimetric Method)

Request Specifications

Tell us the meter size, test method and required testing capacity.

DN50–200 heat meter test bench, flat layout configuration, gravimetric, fully automatic. Request configuration details from KINMY.

Nominal Diameter
DN50–200
Test Method
Gravimetric Method
Layout
Flat Layout
Automation
Fully Automatic

Overview

DN50–200 Fully Automatic Flat Layout Heat Meter Test Bench (Gravimetric Method) is listed in the KINMY Heat Meter Test Bench range with a configuration identified by DN50–200, Gravimetric Method, Flat Layout, Fully Automatic. Contact KINMY for a project-specific specification sheet and quotation.

Configuration

Nominal Diameter DN50–200
Test Method Gravimetric Method
Layout Flat Layout
Automation Fully Automatic

Measurement and Test Methods

Measurement principles Gravimetric Method
Reference flow range 0.010–630 m³/h
Measurement modes Start-Stop Method, Reversal Method

Reference Standards and Instruments

Reference equipment listed for this catalog configuration. The supplied instrument set is confirmed with the project specification.

Weighing Instruments Electronic balances; listed maximum capacities: 60 kg, 600 kg, 12000 kg
Temperature reference equipment Standard platinum resistance thermometer (SPRT); digital multimeter for temperature acquisition; constant-temperature baths

Product Highlights

  • High Production Efficiency: 200 water meters can be tested in eight hours.
  • Fast Input Method: Wireless barcode scanner input of meter numbers, fast, accurate, and convenient.
  • Energy Saving and Consumption Reduction: Saves water, electricity, and labor.
  • Compact Size: Saves space, fully automated, shares a network, and saves auxiliary materials.
  • Novel Structure: Utilizes European standard aluminum profile frame and 304 stainless steel piping, resulting in a novel and elegant appearance.
  • The equipment has a reserved function for calibrating ultrasonic water meters and fully electronic meters.

Reference Specifications

Measurement Uncertainty Urel ≤ 0.2% (k=2)
Flow Stability 1.0% for Start-Stop Method; 0.2% for Other Methods
Calibration Medium Pure Tap Water
Operating Humidity ≤ 93% RH
Operating Water Temperature 20℃± 10℃
Device Operating Temperature 4˜50℃
Water Source Operating Pressure 0.0-0.5 MPa (Adjustable)
Air Source Operating Pressure 0.4-0.7 MPa
Number of Meters Under Test DN50: 3 units | DN65, DN80: 2 units | DN100, DN150, DN200: 1 unit
Meter Clamping Mechanism Dual-Cylinder External-Push Tandem Meter Clamping Device; Single Pneumatic Clamping Device for 10 Front 5 Rear Positions
Vacuum System Differential-Pressure Vacuum Generator, Vacuum Priming, Maintains Water Meters in Full-Water State
Supported Test Modes Fully Automatic, Semi-Automatic, Touchscreen Manual

Utilities and System Configuration

Water pump configuration H=30 m; Q=1 m³/h; P=0.5 kW, 1 unit | H=30 m; Q=40 m³/h; P=7.5 kW, 1 unit | H=35 m; Q=200 m³/h; P=30 kW, 1 unit | H=30 m; Q=600 m³/h; P=75 kW, 1 unit
Water tank capacity 45 m³
Flow diverter DN25, DN50, DN100, DN200 Cross-Type Pneumatic Open Reversers, Low Noise High Sensitivity, Stroke Difference 10 ms, Uncertainty ≤ 0.002%
Timing system (10-100) kHz (Adjustable); Accuracy Better Than 10⁻⁶
Pulse acquisition signal Pulse, f = (0˜10) kHz
Data acquisition hardware 3 Mobile Phones (40 Million Pixels, 8G/128G Storage)
Tightness test pressure range (0˜2.0) MPa

Request Specifications

Final configuration, test range and supplied components can vary by project and selected method. Please send your meter sizes, required test method and expected testing capacity for confirmation.